离子对色谱检测

时间2026-10-31 13:28:28 阅读 来源中析研究所

离子对色谱是常见的工业材料检测需求。北京中科光析科学技术研究所作为第三方检测机构,检测范围包括反相离子对色谱法测定离子型表面活性剂、酸性化合物离子对色谱分离检测、碱性化合物离子对色谱分离检测、药物活性成分离子对色谱分析、氨基糖苷类抗生素离子对色谱测定等20+个品类,检测完成后出具科研检测报告。

检测范围

  • 反相离子对色谱法测定离子型表面活性剂
  • 酸性化合物离子对色谱分离检测
  • 碱性化合物离子对色谱分离检测
  • 药物活性成分离子对色谱分析
  • 氨基糖苷类抗生素离子对色谱测定
  • 水溶性维生素离子对色谱检测
  • 有机酸类化合物离子对色谱分离
  • 有机碱类化合物离子对色谱分离
  • 生物胺离子对色谱定量分析
  • 核苷酸类物质离子对色谱测定
  • 无机阴离子离子对色谱分析
  • 无机阳离子离子对色谱分析
  • 金属络合物离子对色谱分离
  • 季铵盐类化合物离子对色谱检测
  • 磺酸盐类化合物离子对色谱检测
  • 多肽及蛋白质离子对色谱分离
  • 体液样本中药物代谢物离子对色谱测定
  • 水质样品中极性污染物离子对色谱分析
  • 食品样品中添加剂离子对色谱检测
  • 化工原料中离子型杂质离子对色谱分析
  • 农药及其降解产物离子对色谱测定

    检测标准(部分)

    • WJ 2122-1993 水质 2,4-二羟基-1,3,5-三硝基苯(斯蒂芬酸)的测定反相离子对液相色谱法
    • DIN EN 13368-3:2018-07 Fertilizers - Determination of chelating agents in fertilizers by chromatography - Part 3: Determination of [S,S]-EDDS by ion pair chromatography
    • DIN EN 15451:2008-11 Fertilizers - Determination of chelating agents - Determination of iron chelated by EDDHSA by ion pair chromatography
    • ISO 18329:2004 Milk and milk products — Determination of furosine content — Ion-pair reverse-phase high-performance liquid chromatography method
    • BS EN 13368-3:2017 Fertilizers. Determination of chelating agents in fertilizers by chromatography-Determination of [S,S]-EDDS by ion pair chromatography
    • BS EN 15451:2008 Fertilizers. Determination of chelating agents. Determination of iron chelated by EDDHSA by ion pair chromatography
    • ГОСТ EN 15452-2013 Удобрения. Определение хелатированных агентов. Определение железа, хелатированного о,р-EDDHA, посредством реверсивной фазы HPLC
    • ГОСТ EN 15451-2013 Удобрения. Определение хелатированных агентов. Определение железа, хелатированного EDDHSA, ион-парной хроматографией
    • UNE-EN 15451:2008 Fertilizers - Determination of chelating agents - Determination of iron chelated by EDDHSA by ion pair chromatography
    • EN 15451:2008 Fertilizers - Determination of chelating agents - Determination of iron chelated by EDDHSA by ion pair chromatography
    • ГОСТ EN 13368-2-2016 Удобрения. Определение хелатообразователей методом ионной хроматографии. Часть 2. Определение железа, хелатированного o,o-EDDHA, o,o-EDDHMA и HBED, методом ионной парной хроматографии
    • DIN EN 13368-2:2018-03 Fertilizers - Determination of chelating agents in fertilizers by chromatography - Part 2: Determination of Fe chelated by [o,o] EDDHA, [o,o] EDDHMA and HBED, or the amount of chelating agents, by ion pair chromatography
    • BS ISO 18329:2004 Milk and milk products. Determination of furosine content. Ion-pair reverse-phase high-performance liquid chromatography method
    • BS 07/30171559 DC BS EN 15451. Fertilizers. Determination of chelating agents. Determination of iron chelated by EDDHSA by ion pair chromatography
    • EN 13368-3:2017 Fertilizers - Determination of chelating agents in fertilizers by chromatography - Part 3: Determination of [S,S]-EDDS by ion pair chromatography
    • UNE-EN 13368-2:2007 Fertilizers - Determination of chelating agents in fertilizers by chromatography - Part 2: Determination of Fe chelated by o,o-EDDHA and o,o-EDDHMA by ion pair chromatography
    • GB/T 24583.8-2019(英文版) 钒氮合金 硅、锰、磷、铝含量的测定 电感耦合等离子体原子发射光谱法
    • UNE-CEN/TR 15106:2005 IN Fertilizers - Determination of chelating agents EDDHA and EDDHMA by ion pair chromatography - Comparison of non-standardized Lucena method with EN 13368-2:2001
    • EN 13368-2:2017 Fertilizers - Determination of chelating agents in fertilizers by chromatography - Part 2: Determination of Fe chelated by [o,o] EDDHA, [o,o] EDDHMA and HBED, or the amount of chelating agents, by ion pair chromatography
    • CEN/TR 15106:2005 Fertilizers - Determination of chelating agents EDDHA and EDDHMA by ion pair chromatography - Comparison of non-standardized Lucena method with EN 13368-2:2001

    检测信息

    离子对色谱是一种通过在流动相中加入与被测离子电荷相反的离子对试剂,使离子溶质转化为中性离子对化合物,从而实现极性较大、亲水性强的离子型化合物分离的色谱分析技术,广泛应用于制药、环境、化工等领域的复杂样品分析。

    该检测旨在定性定量分析样品中的离子型目标物,涉及反相色谱分离机制、紫外可见检测器信号采集以及外标法或内标法的数据定量处理等技术手段,以获取准确的组分浓度数据。

    检测流程包含色谱柱平衡、离子对试剂浓度优化、流动相pH值调节、标准曲线绘制、样品进样分离及保留时间定性分析,核心参数涵盖容量因子、理论塔板数、分离度与拖尾因子。

    常见问题

    离子对色谱检测需要多长时间?通常7-15个工作日

    具体检测周期受样品基体复杂程度、目标化合物数量及前处理耗时影响,常规样品的离子对色谱分析通常在7至15个工作日内完成并出具数据结果。

    离子对色谱检测费用大概多少?根据检测项目数量确定

    检测费用依据具体的检测项目数量、样品前处理难度及所需使用的仪器机时来核算,项目越多、基体越复杂,相应的检测成本越高。

    离子对色谱分析中如何改善色谱峰拖尾现象?

    可通过调节流动相pH值抑制化合物解离、降低进样量避免柱过载、或优化离子对试剂浓度及比例来改善目标化合物与固定相的作用,进而消除拖尾现象。

    离子对色谱检测项目

    • 保留时间,用于定性鉴别目标化合物的色谱峰位置
    • 色谱峰面积,通过积分计算确定目标离子的相当含量
    • 容量因子,用于评估目标化合物在固定相中的保留能力
    • 理论塔板数,用于判定色谱柱对目标化合物的分离效能
    • 分离度,用于衡量相邻两个色谱峰的完全分离程度
    • 拖尾因子,用于判定色谱峰的对称性及峰形优劣
    • 检出限,用于确定方法能够检出的很低离子浓度
    • 定量限,用于确定能够准确定量分析的很低浓度界限
    • 线性相关系数,用于评价标准曲线与浓度信号的线性关系
    • 加标回收率,用于评估检测方法在基体中的准确度
    • 精密度,用于衡量多次平行进样测定结果的离散程度
    • 重复性,用于评价相同条件下连续进样的结果一致性
    • 中间精密度,用于评估不同日期或不同人员操作的误差
    • 稳定性,用于考察样品溶液在放置过程中的化学降解情况
    • 专属性,用于验证存在干扰物时准确测定目标离子的能力
    • 流动相pH值,用于控制离子型化合物的解离状态与保留行为
    • 离子对试剂浓度,用于调节目标离子在色谱柱中的保留时间
    • 柱温,用于控制分离过程中的传质速率与色谱峰扩散
    • 流速,用于调节系统压力及目标化合物的出峰时间
    • 进样量,用于控制色谱柱的负载量与峰展宽程度

    总结

    离子对色谱检测覆盖酸性化合物、碱性化合物、离子型表面活性剂及水溶性药物等极性物质的分离与定量分析内容。

    相关检测

相关阅读

?猜你想问
在线咨询